Connectors : ENOVIA ER : Configuring Security : Configure the Connector Security Parameters
 
Configure the Connector Security Parameters
First select a security mode at the connector level.
It assumes that you have already configured your connector according to the required connectivity mode.
1. Open your ER Connector instance.
2. In the Configuration tab, expand Security parameters.
3. Click Add item, and from Component class name select a security mode.
Connector Security Modes and Parameters
Mode
Description
Default Security
This mode allows the definition of the two following parameters only.
Note: These parameters are common to all security modes, except for Project Based Security.
All BusinessObjects visible by default: If no security token is generated, this parameter adds the Everybody token on all BOs. It makes documents visible by everyone. If a security handler generates a security token, this parameter has no effect.
All Connections visible by default: If no security token is generated, this parameter adds the Everybody token on all Connection documents. It makes documents visible by everyone. If a security handler generates a security token, this parameter has no effect.
ENOVIA SBA Security
This mode comes from the legacy SBA connector. It is based on the ENOVIA policy security model.
Project Based Security
A simple security, based on the project attribute. Users can only see the documents that are in their projects (that is, Collaborative Spaces, for the 3DSpace).
To distinguish Collaborative Spaces that may have the same name in different 3DSpaces, you can specify a prefix to apply to security tokens.
Security V2
Access list URI: Choose whether to build AccessList URI compatible with the SBA mode, for version V6R2018x and higher.
Prefix: Specify a URI prefix when you want to index data with the same Consolidation Server as another ENOVIA connector.
(Required) Link with business objects: Builds a graph out of Access Lists.